CT Small Lung Nodule Biomarker Ctte
Jump to navigation
Jump to search
Co-chairs: Samuel G. Armato, III, PhD; David Gierada, MD; James L. Mulshine, MD
Secretary: Julie Lisiecki
Meetings
Recent Call Summaries:
- 04.19.2018 QIBA CT Small Lung Nodule Call Summary
- 04.05.2018 QIBA CT Small Lung Nodule Call Summary
- 03.08.2018 QIBA CT Small Lung Nodule Call Summary
- 02.01.2018 QIBA CT Small Lung Nodule Call Summary
- 01.16.2018 QIBA CT Small Lung Nodule Call Summary
- 01.09.2018 QIBA CT Small Lung Nodule Call Summary
- 11.13.2017 QIBA CT Small Lung Nodule Call Summary
Small Lung Nodule BC Call Summaries Archive
Profile Development
Small Lung Nodule Assessment in CT Screening Profile
Small Lung Nodule Profile
- QIBA Small Lung Nodule Profile Draft 2018.02.11
- QIBA Small Lung Nodule Profile Comments and Resolutions Spreadsheet Draft 2018.02.11
- QIBA Small Lung Nodule Profile Draft 2017.11.15
Status - Final Review in progress
- QIBA Small Lung Nodule Profile Draft 2017.10.31
- QIBA Lung Nodule Profile Comment Response 2017.10.07
- QIBA Lung Nodule Profile Draft 2017.09.27
Supporting documents:
- Ref3_SPIE 2017 Proceedings
- Ref5_Avila_et al_IWCLC Tape QA Abstract
- Ref6_Avila_etal_WCTI Hot Topic Abstract
- Ref7_Avila_et al_A Novel Ultra Low Cost CT Image Quality Measurement Dev
- Ref8_Avila_et al_Automatic Estimation of Measurement Error on CT Imaging
- QIBA Lung Nodule Profile Draft 2017.08.02
- Comments on mid-May draft from Kevin 2017.06.06
Status - Public Comment complete
- QIBA Profile: CT Lung Nodule Assessment in Screening Public Comment 2016.06.01 (ended Sept 2016)
Past
- Archived Versions of Profile-related documents.
Reference Materials
- Henschke CI, Yankelevitz DF, Yip R, Archer V, Zahlmann G, Krishnan K, Helba B, Avila R, Tumor volume measurement error using computed tomography imaging in a phase II clinical trial in lung cancer. J Med Imaging (Bellingham). 2016 Jul;3(3):035505. Journal of Medical Imaging
Conformance Materials
The QIBA CT Small Lung Nodule Profile refers to several online resources that are needed to achieve conformance. Links to these resources can be found here.
Clinical Site Conformance
Verified Vendor Systems
- Link To QIBA Verified Conformant CT Scanners and Protocols
- Link to QIBA Verified Conformant Nodule Analysis Software
Phantom Data Upload Site
- Link to QIBA Data Upload Site For Clinical Sites
Small Lung Nodule Online Calculator
- Link to QIBA Small Lung Nodule Online Calculator
CT Scanner Vendor Conformance
Phantom Data Upload Site
- Link to QIBA Data Upload Site For CT Scanner Vendors
Software Analysis Vendor Conformance
Phantom Nodule Dataset
- Phantom Nodule Dataset V1
- Link to QIBACTSLN-PhantomNoduleDatasetLocationsV1.xls
- Link to QIBACTSLN-PhantomNoduleDatasetMeasureReportingFileV1.xls
Clinical Nodule Dataset
- Clinical Nodule Dataset V1
- Link to QIBACTSLN-ClinicalNoduleDatasetLocationsV1.xls
- Link to QIBACTSLN-ClinicalNoduleDatasetMeasureReportingFileV1.xls
Reporting Data Upload Site
- Link to QIBA Data Upload Site For Software Analysis Vendors