Difference between revisions of "VolCT - Group 1B"
Jump to navigation
Jump to search
Mmcnittgray (talk | contribs) |
Mmcnittgray (talk | contribs) |
||
Line 29: | Line 29: | ||
* Progress Reports | * Progress Reports | ||
+ | *[[Media:Update Group 1B 4-19-2011-Dr-McNitt-Gray.pdf|QIBA CT Volumetrics,Group 1B:(Patient Image Datasets), 4.19.2011 - Dr. McNitt-Gray]] | ||
* Analysis Reports | * Analysis Reports | ||
− | + | *[[Media:Exp1B CoffeeBreak Descriptive Statistics 24Sep10 20101004.pdf|Exp 1B Coffee Break Descriptive Statistics - Oct 4, 2010]] | |
* Related Profile: [[CT_Lung_Nodule_Volume_Quantification_Profile#Activity:_Measurement| Lung Vol Quantification - Measurement Activity]] | * Related Profile: [[CT_Lung_Nodule_Volume_Quantification_Profile#Activity:_Measurement| Lung Vol Quantification - Measurement Activity]] | ||
Line 37: | Line 38: | ||
*[[Vol-CT - 1B Group Call Summaries]] | *[[Vol-CT - 1B Group Call Summaries]] | ||
− | + | ||
Line 46: | Line 47: | ||
*[[Media:Naming Convention QIBA 1B Experiment 2 26Aug09.xls|Naming Convention for the QIBA Group 1B Experiment]] | *[[Media:Naming Convention QIBA 1B Experiment 2 26Aug09.xls|Naming Convention for the QIBA Group 1B Experiment]] | ||
− | |||
− |
Revision as of 04:42, 20 April 2011
Current Goals & Status:
- Question: What is the minimum detectable level of change in patient datasets under a “No Change” condition?
- AIMS: For patient datasets acquired over a very short time interval (“no change” condition”) investigate variance in measuring change in volume, diameter and bi-directional diameters of lesions
- Investigate inter-observer variability in each task
- Investigate Intra-observer variability in each task
- Methods - Materials
- Image Data from MSK Coffee Break Experiment
- 32 NSCLC patients, imaged twice on same scanner over period < 15 minutes
- Thin slice (1.25 mm thick) image data
- Selected one lesion per patient
- no outcome data
- Publicly Available on NCIA
- Methods - Materials
- Methods - Readings
- 5 readers
- Read CT at timepoint 1, CT at timepoint 2 and repeat either CT timepoint 1 or timeoint 2 to assess intra-reader variability
- Methods - Measurements
- Measure Single Longest Diameter, manually (SLD)
- Measure Longest Diameter and Perpendicular Diameter; take product to obtain Product of Diameters (POD)
- Contour Full Boundary of lesion with semiautomated tool; calculate volume (Vol)
- Extract other measures as well (SLD from POD measureement; SLD from VOl and POD from Vol).
- The Order of Readers, Lesions and Measurement Methods were Randomized (Measurements done in Blocks of 10)
- Methods - Readings
- Analyses
- Pooled Analysis across readers and lesions; Percent Difference between Scan 1 and Scan 2 for each measurement method
- Subgroup Analyses: (a) Based on Measureable/Non-Measureable lesions identified by Mike O'Neal of CoreLabs; (b) Difficult, Moderate and Easy as Identified by Mike McNitt-Gray
- Analyses
- Analysis Reports
- Exp 1B Coffee Break Descriptive Statistics - Oct 4, 2010
- Related Profile: Lung Vol Quantification - Measurement Activity
- Proposed Group 1B Questions & Datases (2009-02-10) -- Feedback Welcome -- Dr. McNitt-Gray
- ACRIN 6678 Quality Control Parameters for CT Scan Tumor Volumetric Measurements
- Conference Paper on Reproducibility and Accuracy of Uni- and Bi-Dimensional Tumor Measurements from MRI and CT Volumes, which looks at RECIST, WHO and Volume measurements.