Difference between revisions of "Standardized Uptake Value (SUV)"
Jump to navigation
Jump to search
Line 15: | Line 15: | ||
== Letter to vendors requesting detailed SUV computation description == | == Letter to vendors requesting detailed SUV computation description == | ||
− | [[Media:QIBA_FDG_Vendor_SUV_20081103_DAC.doc]] Letter sent to vendors | + | *[[Media:QIBA_FDG_Vendor_SUV_20081103_DAC.doc]] Letter sent to vendors |
− | [[Media:QIBA_FDG_Vendor_SUV_20081103_DAC_JTY.doc]] Letter with additional questions from Jeff Yap | + | *[[Media:QIBA_FDG_Vendor_SUV_20081103_DAC_JTY.doc]] Letter with additional questions from Jeff Yap |
== Vendor responses on SUV computation == | == Vendor responses on SUV computation == |
Revision as of 11:47, 2 October 2012
Back to FDG-PET
QIBA FDG-PET/CT Standardized Uptake Value (SUV) Technical Subcommittee Charge
The objective of this subcommittee is to build a common reference DICOM test image that can be generated by each scanner and read on PET DICOM display stations to check information fidelity (i.e. next step beyond DICOM conformance statement)
Completed:
- Collected DICOM PET/CT images of the same reference phantom from scanners from GE, Philips, Siemens
- Image data collated and compared to DICOM header information
Working Documents
- Digital Reference Objects - 4 Slide Overview - 2009.03.10
- Vendor-neutral pseudo-code for SUV calculation - updated 20120928 - changes from 20091106 tracked
Letter to vendors requesting detailed SUV computation description
- Media:QIBA_FDG_Vendor_SUV_20081103_DAC.doc Letter sent to vendors
- Media:QIBA_FDG_Vendor_SUV_20081103_DAC_JTY.doc Letter with additional questions from Jeff Yap
Vendor responses on SUV computation
- Philips - Media:QIBA_FDG_Vendor_SUV_Philips.doc
Vendor supplied information
Subcommittee Call Summaries
- 11.05.2009 FDG-PET/CT SUV Subcommittee Call Summary
- 09.30.2009 FDG-PET/CT SUV Subcommittee Call Summary
- 08.06.2009 FDG-PET/CT SUV Subcommittee Call Summary
- 04.17.2009 FDG-PET/CT DRO Subcommittee Call Summary
- 03.27.2009 FDG-PET/CT DRO Subcommittee Call Summary
- 03.13.2009 FDG-PET/CT DRO Subcommittee Call Summary
SUV Subcommittee Members
- Paul Kinahan, PhD, Subcommittee Co-chair <kinahan@u.washington.edu>
- David Clunie, MBBS, Subcommittee Co-chair <dclunie@radpharm.com>
- Ronald Boellaard, PhD <r.boellaard@vumc.nl>
- Michael Casey, PhD <michael.e.casey@siemens.com>
- Paul E. Christian <Paul.Christian@hci.utah.edu>
- Patricia E. Cole, PhD, MD <patriciaellencole@gmail.com>
- Simon DeBruin, MSEE <sdebruin@segamicorp.com>
- John M. Hoffman, MD <john.hoffman@hci.utah.edu>
- Steve Kohlmyer <Steve.Kohlmyer@med.ge.com>
- Piotr Maniawski <piotr.maniawski@philips.com>
- Dennis Nelson, PhD <dnelson@mimvista.com>
- Eric S. Perlman, MD <perlman@radpharm.com>
- Ling X. Shao, PhD, <ling.shao@philips.com>
- John G. Wolodzko, PhD <wolodzko@radpharm.com>
- Jeffrey Yap, PhD <Jeffrey_Yap@dfci.harvard.edu>
- Brian Zimmerman, PhD <bez@nist.gov>