Difference between revisions of "CT Volumetry Biomarker Ctte"
Jump to navigation
Jump to search
Line 11: | Line 11: | ||
*[[Call Summaries]] | *[[Call Summaries]] | ||
− | ==Profile | + | ==Profile Development== |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | Public Comment | + | ===Advanced Disease Profile (Now Resolving Public Comment)=== |
− | *[[Media: | + | *[[Media:2011 07 28 Profile CT advanced disease V2 0 AB.doc|Computed Tomography: Change Measurements in the Volume of Solid Tumors-Profile V2.0]] ''(Profile Draft) 07/28/2011'' |
+ | *[[Media:QIBA Vol-CT AdvDiseaseV2 0 Public Comment Resolution 2011-11-21.doc|QIBA Vol-CT AdvDiseaseV2.0 Public Comment Resolution]] ''(Public Comments & Resolutions) 2011-11-21'' | ||
− | + | *[[Media: 2010.09.09_UPICT_V1_4_1_FIELD_TEST.doc|VIA Protocol v1.4.1]] ''(Early field test protocol draft) 09-11-2010'' | |
− | *[[Media: 2010.09.09_UPICT_V1_4_1_FIELD_TEST.doc|VIA Protocol v1.4.1]] '' | ||
Revision as of 02:02, 8 December 2011
Project Snapshot
- Compliance Documents: QIBA Approach to Compliance-- Andrew J. Buckler, MS, Program Director, QIBA 08.15.11
- "Why QIBA?" - Specifics associated with CT device and software manufacturers.
- Project plan .jpg version as of 11-8-10
See the Datasets page of the QIBA Resource Catalog
Meetings / Call Summaries
Profile Development
Advanced Disease Profile (Now Resolving Public Comment)
- Computed Tomography: Change Measurements in the Volume of Solid Tumors-Profile V2.0 (Profile Draft) 07/28/2011
- QIBA Vol-CT AdvDiseaseV2.0 Public Comment Resolution (Public Comments & Resolutions) 2011-11-21
- VIA Protocol v1.4.1 (Early field test protocol draft) 09-11-2010
Archived Versions of QIBA draft documents.
Working Documents
Active:
- VolCT - Group 1B - Focus on Volume Change Analysis of Pulmonary Nodules in Diagnostic Settings
- VolCT - Group 1C - Model Sources of Variability from a Systems Engineering Analysis
- VolCT - Group 3A - Characterize variability due to algorithm using phantoms
- VolCT - Group 3B - Characterize clinical utility/efficacy with respect to clinical endpoints
- VolCT - Colorado Group - Quantifying variability in measurement of pulmonary nodule
No longer active:
- Advanced Disease:
- VIA Profile v1.6 02/28/2011
- VIA Profile v1.5 01/09/2011
- VIA Protocol v1.4 Word version known as field test v1.0, 09-09-2010
- Small Nodule:
- Small Pulmonary Nodule Profile v0.6 03/12/2011
- Small Pulmonary Nodule Profile v0.4 02/14/2011
- UPICT Template for CT Lung Nodule Protocol Google doc version of v1.4 WIP
- Quantification in Imaging-Dr Dirk Colditz August 23, 2010
- Work Breakdown for Volumetric CT 07.12.10
- VolCT - Group 1A - Analyze Bias/Variance where Ground Truth is Known Deterministically
- 2009 12 31 Review of Volumetric Image Analysis in Patients with Solid Tumors - long version
- VIA Profile v1.1 Word version 09-03-2009
- Profile: CT Lung Nodule Volume Measurement for Primary/Regional Nodes and Metastatic Sites Last updated 6/2009
- Profile: CT Lung Nodule - Small Nodule in Neoadjuvant Setting Last updated 6/2009
- Validation Roadmap - P. David Mozley, MD
- Thoughts on the QIBA Process: Profiles, UPICT & Measurements by Kevin O’Donnell-20090629
- VolCT - Group 2 - Set Standards for using Volumetric Imaging in Clinical Trials
- Profile Strategy for Vol CT
- Initial Target Selection - describing the early prioritization discussions and settling on Lung Tumor Volumes
- Sources of Variability - Andrew Buckler
Reference Materials
- Dr Petrick's 2011 SPIE Presentation Materials
- “Evaluation of 1D, 2D and 3D nodule size estimation by radiologists for spherical and non-spherical nodules through CT thoracic phantom imaging” - Talk
- “Evaluation of 1D, 2D and 3D nodule size estimation by radiologists for spherical and non-spherical nodules through CT thoracic phantom imaging” - Paper
- Are we ready? A time for measurement of physiological parameters of the lung using multidetector row CT scans. Hatabu H. Acad Radiol. 2009 Mar; 16(3):249. Academic Radiology
- Radiology 2007 - Coronary Calcium Scoring - This paper by Dr. McCollough et al is may be seen to be analaogous to our work in that it addresses similar issues (e.g. achieving "standard" noise levels). It could be thought of as an early draft of a Calcium Scoring profile, including both groundwork and equipment specifications.
- Helical multidetector row quantitative computed tomography (QCT) precision. Bligh M, Bidaut L, White RA, Murphy WA Jr, Stevens DM, Cody DD. Acad Radiol. 2009 Feb; 16(2):150-9. Academic Radiology
- Comparison of the accuracy of CT volume calculated by circumscription to prolate ellipsoid volume (bidimensional measurement multiplied by coronal long axis). Rkein AM, Harrigal C, Friedman AC, Persky D, Krupinski E. Acad Radiol. 2009 Feb; 16(2):181-6. Academic Radiology