An Ultrasound Quantitative Biomarker Planning Meeting was held on Thursday, March 29, 2012 at the 2012 American Institute of Ultrasound in Medicine (AIUM) Annual Convention, in Phoenix, AZ.   
 
An Ultrasound Quantitative Biomarker Planning Meeting was held on Thursday, March 29, 2012 at the 2012 American Institute of Ultrasound in Medicine (AIUM) Annual Convention, in Phoenix, AZ.   
The purpose of this meeting was to plan an effort by the biomedical ultrasound community to create and support implementation of a QIBA Profile for a quantitative biomarker in ultrasound imaging. Shear Wave Speed was selected as the qualifying biomarker at this meeting.
+
T
 +
he purpose of this meeting was to plan an effort by the biomedical ultrasound community to create and support implementation of a QIBA Profile for a quantitative biomarker in ultrasound imaging. Shear Wave Speed was selected as the qualifying biomarker at this meeting
 +
 
 +
Public Comment for Version 1.0 of the Profile, QIBA US Measurement of Shear Wave Speed for Estimation of Liver Fibrosis, closed December 18, 2019.
  
 
==Profile Development==
 
==Profile Development==
Line 12: Line 15:
  
 
See Profiles page for copy of the Profile:  http://qibawiki.rsna.org/index.php/Profiles
 
See Profiles page for copy of the Profile:  http://qibawiki.rsna.org/index.php/Profiles
 +
  
 
'''''[[Working Documents Archive]]'''''
 
'''''[[Working Documents Archive]]'''''
 
*[[Media:SWS_BC_ProfileChecklist.pdf | QIBA SWS Profile Checklist for Fibrosis]] ''October 27, 2017''
 
 
*[[Media:QIBA Profile_04112016 BSG Edited discussed with MD4-10-16.docx | QIBA DRAFT Profile: Ultrasound Measurement of Shear Wave Speed for Estimation of Liver Fibrosis]] ''April 14, 2016''
 
  
 
==SWS Task Forces==
 
==SWS Task Forces==
Line 29: Line 29:
 
'''Approved call summaries:'''
 
'''Approved call summaries:'''
  
 +
*[[Media:06 05 2020 QIBA US SWS BC Call Summary-FINAL.pdf | June 5, 2020]]
 
*[[Media:02 07 2020 QIBA US SWS BC Call Summary-FINAL.pdf | February 7, 2020]]
 
*[[Media:02 07 2020 QIBA US SWS BC Call Summary-FINAL.pdf | February 7, 2020]]
  

Revision as of 21:11, 11 June 2020

Co-chairs: Brian Garra, MD; Andrzej (Andy) Milkowski, MS
RSNA Staff Support: Julie Lisiecki

Project Snapshot - Shear Wave Speed (SWS)

An Ultrasound Quantitative Biomarker Planning Meeting was held on Thursday, March 29, 2012 at the 2012 American Institute of Ultrasound in Medicine (AIUM) Annual Convention, in Phoenix, AZ. T he purpose of this meeting was to plan an effort by the biomedical ultrasound community to create and support implementation of a QIBA Profile for a quantitative biomarker in ultrasound imaging. Shear Wave Speed was selected as the qualifying biomarker at this meeting.

Public Comment for Version 1.0 of the Profile, QIBA US Measurement of Shear Wave Speed for Estimation of Liver Fibrosis, closed December 18, 2019.

Profile Development

Status - Integrating Public Comments received

See Profiles page for copy of the Profile: http://qibawiki.rsna.org/index.php/Profiles


Working Documents Archive

SWS Task Forces

Recent US-SWS Meetings

Approved call summaries:


US SWS Call Summaries Archive

Conferences

Tools

Literature for this the QIBA SWS Biomarker Committee has been compiled using Mendeley, and is called 'QIBA SWS'. This is a public group that anyone can join. If you would like a specific invitation to join, please email Dr. Palmeri.

  • Web browsers recommended: Firefox or Google Chrome

US Phantoms

  • Exploratory QIBA Elastic and Viscoelastic homogeneous SWS calibration liver phantoms, CIRS model 039 and prototype.
  • Exploratory Volume Flow Doppler Phantom with nonparabolic flow - Sun Nuclear prototype.
  • Research flow phantom for contrast ultrasound testing, M. Averkiou, Univ. of Wash.

Phantom Simulation Data -> http://www.rsna.org/qidw/ https://github.com/RSNA-QIBA-US-SWS/QIBA-DigitalPhantoms

QIBA Finite Element Tool Repository Online & Elastic / Viscoelastic Simulation Data - [1]

Digital Phantoms

See ultrasound digital phantoms:

Software

See reference imaging system software:

Reference Materials

Article citations:

  • Sebastiani G, Alberti A. How far is noninvasive assessment of liver fibrosis from replacing liver biopsy in Hepatitis C? Journal of Viral Hepatitis,2012, 19 (Suppl. 1), 18–32. PubMed citation

Funded-Project Reports:

Presentations and Reports:

QIBA Funded Projects

Round 3

Round 4

Round 5